- If the camera is currently running, Click Stop in the IsgU3VGUI.
- Change Aquisition Mode to Continuous.
- Change Trigger Source to Software.
- Change Trigger Mode to ON.
- Click Start to open a viewer window.
- Select Generate Software Trigger and click Execute Command to trigger a frame.